BGLMS - ISOCYANATE ACTIVATOR/HARDENER, 192S

Product Identification

Product ID:ISOCYANATE ACTIVATOR/HARDENER, 192S
MSDS Date:01/01/1987
FSC:8010
NIIN:01-092-1931
MSDS Number: BGLMS

Responsible Party
DU PONT E I DE NEMOURS & CO FABRICATED PROD DEPT
1007 MARKET ST BRANDYWINE BLDG 3332
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637

Info Phone: 302-999-3847 OR 302-999-4338

Cage: 90227

Contractor
DU PONT E I DE NEMOURS & CO FABRICATED PROD DEPT
WILMINGTON, DE 19898 US

Telephone: 800-441-3637

Cage: 90227

Ingredients

N-BUTYL ACETATE (SARA III)

CAS: 123-86-4

RTECS: AF7350000

OSHA PEL 150 PPM/200 STEL

ACGIH TLV: 150 PPM/200STEL;9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHYL ACETATE (SARA III)

CAS: 141-78-6

RTECS: AH5425000

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


AROMATIC HYDROCARBONS (VAPOR PRESSURE = 5)

ACGIH TLV: 50 PPM


POLYMERIC HEXAMETHYLENE DIISOCYANATE

RTECS: MD1740000

Fraction By Weight: <0.2%

Hazards

Effects of Overexposure:NOSE/THROAT IRRITATION. HEADACHE, DIZZINESS,
NAUSEA, STAGGERING GAIT, CONFUSION, UNCONSCIOUSNESS

First Aid

First Aid:IN CASE OF EYE CONTACT, IMMEDIATELY FLUSH W/PLENTY OF WATER
FOR AT LEAST 15 MINUTES; CALL A PHYSICIAN. IN CASE OF SKIN CONTACT
WASH W/SOAP & WATER. IF IRRITATION OCCURS, CONTACT A PHYSICIAN. IF
AFFECT ED BY INHALATION OF VAPOR, REMOVE TO FRESH AIR

Fire Fighting

Flash Point:20-73F (CC)
Lower Limits:1.1%
Upper Limits:14%
Extinguishing Media:FOAM, CO2, DRY CHEMICAL
Fire Fighting Procedures:WEAR SCBA. WATER COOL CONTAINERS/PREVENT
PRESSURE BUILD UP
Unusual Fire/Explosion Hazard:FINE MISTS OR SPRAYS MAY BE FLAMMABLE AT
TEMPERATURES BELOW THE FLASH POINT.

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
PREVENT SKIN CONTACT AND BREATHING OF VAR. CONFINE AND REMOVE WITH
INERT ABSORBANT.

Handling

Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS & FLAME. CLOSE CONTAINER AFTER EACH USEGROUND
CONTAINERS WHEN POURING.
Other Precautions:WASH THOROUGHLY AFTER HANDLING & BEFORE EATING OR
SMOKING. DON'T STORE ABOVE 120F. DON'T SAND/FLAME CUT/BRAZE OR WELD
DRY COING W/OUT A NIOSH/MSHA APPROVED RESP/APPROPRIATE VENTILATION.

Exposure Controls

Ventilation:PROVIDE VENTILATION TO KEEP BELOW TLV
Protective Gloves:NEOPRENE
Eye Protection:SPLASH GUARDS/SIDE SHIELD
Supplemental Safety and Health
KEY1:F3.

Chemical Properties

HCC:F2
Boiling Pt:B.P. Text:168-401F
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:SLIGHT
Percent Volatiles by Volume:72.9

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLE FORESEEABLE
Hazardous Decomposition Products:CO, CO2, SMOKE

Disposal

Waste Disposal Methods:DON'T ALLOW MATERIAL TO CONTAMINATE GROUND WATER
SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REQUIREMENTS. DON'T INCINERATE IN CLOSED
CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.